Report
The Report tab under the Results tab shows the computed results depending on the selected flow experiment set-up.
It starts with the Permeability (3x3) tensor. For all flow simulations find a report providing the flow simulation results. In the reports for the selected computation directions, for example, find values for Average flow velocity at a given pressure drop, Volume flow rate, and Flow resistivity.
Information about the convergence of the iterative solver is also displayed for each selected computation direction: Threads, Iterations, Number of cells, Runtime, Memory usage, and applied Stopping criterion.
In the last line the Total runtime and Total memory usage are given. Here not only the resources used by the solver are taken into account but also writing volume fields and structure files or already loaded volume fields from previous simulations. Thus, even if only one flow direction is computed, the total runtime and total memory values are usually higher than the solver specific values.